The CentriMag™ Acute Circulatory Support System with Full MagLev™ flow technology delivers excellent haemocompatibility across the widest range of patient applications.

 The free-floating magnetically levitated rotor has an automatic position control that adjusts 50,000 times per second to maintain stable and consistent blood flow, preventing surface-to-surface contact that could cause blood trauma. 

The CentriMag™ Blood Pump.

The CentriMag™ Acute Circulatory Support System with Full MagLev™ flow technology delivers excellent haemocompatibility across the widest range of patient applications.
Priming Volume 31 ml
Inlet / Outlet 3/8″ Barbed
Max. Speed 5,500 rpm
Max. Flow 9.99 lpm
Max Operating Pressure 600 mmHg

The PediVAS™ Blood Pump.

The CentriMag™ Acute Circulatory Support System with Full MagLev™ flow technology delivers excellent haemocompatibility across the widest range of patient applications.
Priming Volume 17 ml
Inlet / Outlet 1/4″ Barbed
Max. Speed 5,500 rpm
Max. Flow 1.7 lpm
Max Operating Pressure 540 mmHg

Addressing the broadest spectrum of clinical challenges.

The system helps you provide optimal patient care for every application¹, including biventricular assist device (BiVAD), left ventricular assist device (LVAD), right ventricular assist device (RVAD) and, extracorporeal membrane oxygenation (ECMO) / extracorporeal life support (ECLS).

Providing a contact-free, friction-free environment, the Full MagLev™ technology can result in 5% low haemolysis², 2.5% low device-related thrombosis² and, improved end-organ function³.

The CentriMag™ Acute Circulatory Support System with Full MagLev™ flow technology delivers excellent haemocompatibility across the widest range of patient applications.
The CentriMag™ Acute Circulatory Support System with Full MagLev™ flow technology delivers excellent haemocompatibility across the widest range of patient applications.
The CentriMag™ system is fully transportable via air or ground ambulance.

The CentriMag™ V2 System.

The system comprises of console, a pump motor driver, a flow probe and a flat screen control monitor.

Designed to be robust and compact allows it to be permanently but discreetly situated in an ITU and, also lends itself to patient transport, as the CentriMag™ is fully transportable via air or ground ambulance using the compact system transporter. The transporter complies with all prevailing standards for air and ground transportation.

Chalice Medical Ltd. are the UK distributor and service agents of the CentriMag™ system, supplied by St Jude Medical / Abbott.

Features and Benefits of the CentriMag®

Connect 2 separate consoles  to the control screen to simultaneously monitor and report 4 different circuit pressures.

An optional service plan** is available to annually service the device and to also provide emergency rental equipment.

An internal Lithium Ion battery provides vital support* in patient transport and/or in the event of a mains power failure.

3 sizes of flow probes are available to monitor fluid flow rates non-invasively through  an externally mounted clip-on sensor.
The large display monitor graphically shows in real-time; fluid flow rates, circuit pressures and pump speed.
Wide blood flow pathways plus the absence of bearings and valves minimise blood turbulence and stasis.
1) Bhama, J. K., Kornos, R. L., Toyoda, Y., Teuteberg, J. J., McCurry, K. R., & Siegenthaler, M. P. (2009). Clinical experience using the Levitronix CentriMag system for temporary right ventricular mechanical circulatory support. The Journal of Heart and Lung Transformation28(9), 971-976. http://dx.doi.org/10.1016/j.healun.2009.04.015

2) John, R., Long, J. W., Massey, H. T., Griffith, B. P., Sun, B. C., Tector, A. J., Joyce, L. D. (2011). Outcomes of a multicenter trial of the Levitronix CentriMag ventricular assist system for short-term circulatory support. The Journal of Thoracic and Cardiovascular Surgery, 141(4), 932-939. http://dx.doi.org/10.1016/j.jtcvs.2010.03.046 

3) John, R., Liao, K., Lietz, K., Kandar, F., Colvin-Adams, M., Boyle, A., Joyce, L. (2007). Experience with the Levitronix CentriMag circulatory support system as a bridge to decision in patients with refractory acute cardiogenic shock and multisystem organ failure. The Journal of Thoracic and Cardiovascular Surgery, 134(2), 351-358. http://dx.doi.org/10.1016/j.jtcvs.2007.01.085 

(Information and video provided by St Jude Medical / Abbott).

*Approximately provides 120 minutes support time running at 3,500 rpm at a flow rate of 5.5 lpm. Further details can be found in the Operating Manual (PL-0280 Rev 6) on page 29.

**Terms and conditions apply for service plans – please contact a Sales Manager for more information.